Steel

Steel

Exhaust Fan (3 star) Problem: We detected excessive fan speed vibration and harmonics on all measurement locations. We recommended first checking the motor and fan bearings for any looseness/lack of rigidity and the belts/sheaves for wear and proper alignment. We also...
Cement

Cement

Kiln 2 ID Fan (3 star) Problem: We detected high levels of high-frequency wideband vibration and harmonics at multiples near the outer race defect frequency on the inboard fan bearing. The vibration level was 411% above average and the highest we’ve seen to...
Mining

Mining

“We repaired the pinion shaft and replaced the bearings on the high speed side of the 101 gearbox. We also installed a new primary drive motor on the intermediate belt. You really saved the day on the 101 belt. Thanks to you we avoided a major catastrophe.” Belt 101...